I Can’t Sleep - Utility Poles | Calm Bedtime Reading for Sleep

Episode Date: April 2, 2024

Relax with this calm bedtime reading on utility poles, created to ease insomnia and bring peace to sleepless nights. In this soothing episode, Benjamin explores the history and purpose of utility pole...s, from their early use in telegraph lines to their continued role in carrying electricity, phone, and internet connections today. His steady, gentle narration provides both learning and comfort—no whispers, no hypnosis, just calm, fact-filled storytelling to quiet the mind. Whether you’re struggling with stress, anxiety, or sleeplessness, press play, unwind, and drift into restful sleep while learning about utility poles. Want More? Request a Topic: https://www.icantsleeppodcast.com/request-a-topic Ad-Free Episodes: https://icantsleep.supportingcast.fm/ Shop Sleep-Friendly Products: https://www.icantsleeppodcast.com/sponsors Join the Discussion on Discord: https://discord.gg/myhGhVUhn7 This content is derived from the Wikipedia article on Utility Poles, available under the Creative Commons Attribution-ShareAlike (CC BY-SA) license. Read the full article: Wikipedia – Utility Poles. Happy sleeping! Learn more about your ad choices. Visit megaphone.fm/adchoices

Transcript
Discussion (0)
Starting point is 00:00:03 You're listening to a Glassbox media podcast. What if I told you that most of the modern day self-help advice you've been hearing could actually make you worse? The key to a better life isn't about feel-good gimmicks that sound catchy. The Mentally Stronger Podcast gives you access to a licensed therapist who shares science-backed tools that will actually change your life. Hi, I'm Amy Morin, psychotherapist, mental strength trainer, and international best-selling author. In each episode, we cover research-back strategies, like how to stop relying on willpower and start creating habits for lasting change. And the five mental strength-building exercises you can do from your couch. I also speak to world-class experts like Dr. Nicole Kane, who shares how to permanently heal anxiety by addressing the root cause.
Starting point is 00:00:57 With over 200 episodes in our catalog, this podcast is for you if you're ready to crush self-doubt, conquer challenges, become stronger than ever with therapist-approved strategies that can change your life. Listen to Mentally Stronger with Therapist Amy Morin, wherever you get your podcasts. Welcome to the I Can't Sleep podcast, where I read random articles from across the web to bore you to sleep with my soothing voice. I'm your host, Benjamin Boster. Today's episode is from a Wikipedia article titled Utility Poll. A utility poll is a cost. Polymer post, usually made out of wood or aluminum alloy, used to support overhead power lines
Starting point is 00:01:41 and various other public utilities, such as electric cable, fiber optic cable, and related equipment such as transformers and streetlights. It can be referred to as a transmission pole, telephone pole, telecommunication pole, power pole, hydropole, telegraph pole, or telegraph post, depending on its application. A Stobie pole is a multi-purpose pole made of two steel joists held apart by a slab of concrete in the middle, generally found in South Australia. Electrical wires and cables are routed overhead on utility poles, has an inexpensive way to keep them insulated from the ground and out of the way of people and vehicles.
Starting point is 00:02:29 Utility poles can be made of wood, metal, concrete, or composites like fiberglass. They are used for two different types of power lines, sub-transmission lines which carry higher voltage power between substations, and distribution lines which distribute lower voltage power to customers. The first poles were used in 1843 by Telegraph pioneer William Fothergill Cook, who used them on a line along the Great Western Railway. utility poles were first used in the mid-19th century in America with telegraph systems, starting with Samuel Morse, who attempted to bury a line between Baltimore and Washington, D.C., but moved it above ground when this system proved faulty. Today, underground distribution lines are increasingly used as an alternative to utility poles in residential neighborhoods due to polls perceived ugliness,
Starting point is 00:03:28 as well as safety concerns in areas with large amounts of snow or ice buildup. Utility poles are commonly used to carry two types of electrical power lines, distribution lines or feeders, and sub-transmission lines. Distribution lines carry power from local substations to customers. They generally carry voltages from 4.6 to 33 kilovolts, KV, for distances up to 30 miles, and include transformers to step the voltage down from the primary voltage to the lower secondary voltage used by the customer. A service drop carries this lower voltage to the customer's premises. Sub-transmission lines carry higher voltage power from regional substations to local substations.
Starting point is 00:04:22 They usually carry 46 kilovolts, or 115 kilovolts for distances up to 60 miles. 230 kilovolt lines are often supported on H-shaped towers made with two or three poles. Transmission lines carrying voltages of about 230 kilovolts are usually not supported by poles, but by metal pylons, known as transmission towers in the U.S. For economic or practical reasons, such as to save space in urban areas, a distribution line is often carried on the same poles as a sub-transmission line, but mounted under the higher voltage lines, a practice called underbilled. Telecommunication cables are usually carried on the same poles that support power lines. Polls shared in this fashion are known as joint-use poles, but may have their own dedicated poles. The standard utility pole in the United States is about 35 feet tall and is buried about
Starting point is 00:05:29 six feet in the ground. However, poles can reach heights of 120 feet or more to satisfy clearance requirements. They are typically spaced about 125 feet apart in urban areas or about 300 feet in rural areas, but distance is very widely based on terrain. Joint use poles are usually owned by one utility, which leases space on it for other cables. In the United States, the National Electrical Safety Code, published by the Institute of Electrical and Electronics Engineers, IEEE, not to be confused with the National Electrical Code, published by the National Fire Protection Association, NFPA, sets the standards for construction and maintenance of utility poles in their equipment. Most utility poles are made of wood, pressure treated with some type of preservative
Starting point is 00:06:26 for protection against rot, fungi, and insects. Southern yellow pine is the most widely used species in the United States. However, many species of long straight trees are used to make utility poles, including Douglas fir, jack pine, lodgepole pine, western red cedar, and Pacific silver fir. Traditionally, the preservative used was creosode, but due to environmental concerns, alternatives such as pentaclorophyll, copper naphthenate, and boric. are becoming widespread in the United States. In the United States, standards for wood preservative materials and wood preservation processes,
Starting point is 00:07:09 along with test criteria, are set by ANSI, ASTM, and American Wood Protection Association, AWPA specifications. Despite the preservatives, wood poles decay and have a life of approximately 25 to 50 years, depending on climate and soil conditions, therefore requiring regular inspection and remedial preservative treatments. Woodpecker damage to woodpoles is the most significant cause of pull deterioration in the U.S. Other common utility pole materials are aluminum, steel, and concrete, with composites such as fiberglass also becoming more prevalent.
Starting point is 00:07:55 One particular patented utility pole variant used in a other, Australia is the Stobie pole, made up of two vertical steel posts with a slab of concrete between them. In southern Switzerland along various lakes, telephone poles are made of granite. Starting in the early 1900s, these five-meter poles were originally used for telegraph wires and later for telephone wires. Because they are made of granite, the poles last indefinitely. On poles carrying both electrical and communications wiring, the electric power distribution lines and associated equipment are mounted at the top of the pole above the communication cables for safety. The vertical space on the pole reserved for this equipment is called the supply space.
Starting point is 00:08:47 The wires themselves are usually uninsulated and supported by insulators, commonly mounted on a horizontal beam cross arm. Power is transmitted using the three-phase system. with three wires or phases labeled A, B, and C. Subtransmission lines comprise only these three wires, plus sometimes an overhead ground wire, OGW, also called a static line or a neutral suspended above them. The OGW acts like a lightning rod,
Starting point is 00:09:24 providing a low-resistance path to ground, thus protecting the phase conductors from lightning. Distribution lines use two systems, either grounded Y on electrical schematics, or Delta, Greek letter Delta on electrical schematics. A delta system requires only a conductor for each of the three phases. A grounded Y system requires a fourth conductor, the neutral, whose source is the center of the Y and is grounded. However, spur lines branching off the main line to provide power to side streets often carry only one or two-phase wires plus the neutral. A wide range of standard distribution voltages are used, from 2,400 volts to 34,500 volts.
Starting point is 00:10:16 On poles near a service drop, there is a pole-mounted step-down distribution transformer to transform the high distribution voltage to the lower secondary voltage provided to the customer. In North America, service drops provide 240 over 120-volt split-phase power for residential and light commercial service using cylindrical single-phase transformers. In Europe and most other countries, 230-volt-3-phase service drops are used. A transformer's primary is connected to the distribution line through protective devices called fuse cutouts. In the event of an overload, the fuse melts and the device pivots open to provide a visual indication of the problem. It can also be opened manually by a liniment using a long, insulated rod called a hot stick to disconnect the transformer from the line.
Starting point is 00:11:13 The pole may be grounded with a heavy bare copper or copper-clad steel wire running down the pole attached to the metal pin supporting each insulator and at the bottom connected to a metal rod driven into ground. Some countries ground every pole while others only ground every fifth pole and any pole with a transformer on it. This provides a path for leakage currents across the surface of the insulators to get to the the ground, preventing the current from flowing through the wood pole which could cause a fire or shock hazard. It provides similar protection in case of flashovers and lightning strikes.
Starting point is 00:11:58 A surge arrestor, also called a lightning arrester, may also be installed between the line ahead of the cutout and the ground wire for lightning protection. The purpose of the device is to conduct extremely high voltages present on the line directly to ground. If uninsulated conductors touch due to wind or fallen trees, the resultant sparks can start wildfires. To reduce this problem, aerial bundled conductors are being introduced. The communications cables are attached below the electric power lines in a vertical space along the pole designated the communication space. The communication space is separated from the lowest electrical conductor
Starting point is 00:12:44 by the communication worker safety zone, which provides room for workers to maneuver safely while servicing the communication cables, avoiding contact with the power lines. The most common communication cables found on utility poles are copper or fiber optic cable, FOC for telephone lines, and coaxial cable for cable television, CATV.
Starting point is 00:13:11 Coaxial or optical fiber cables linking computer networks are also increasingly found on poles in urban areas. The cable linking the telephone exchange to local customers is a thick cable lashed to a thin supporting cable, containing hundreds of twisted pair subscriber lines. Each twisted pair line provides a single telephone circuit or local loop to a customer. There may also be FOCs interconnecting telephone exchanges, like electrical distribution. distribution lines, communication cables connect to service jobs when used to provide local service to customers. Utility poles may also carry other equipment such as streetlights, supports for traffic lights,
Starting point is 00:13:59 and overhead wires for electric trolleys, and cellular network antennas. They can also carry fixtures and decorations specific for certain holidays or events specific to the city where they are located. solar panels mounted on utility poles may power auxiliary equipment where the expense of a power line connection is unwanted. Street lights and holiday fixtures are powered directly from secondary distribution. The primary purpose of pole attachment hardware is to secure the cable and associated aerial plant facilities to poles and to help facilitate necessary plant rearrangements. An aerial plant network requires high-quality reliable hardware to structurally support the distribution cable plant. Provide directional guine to accommodate lateral stresses created on the pole by pole-line configurations and pole-load configuration.
Starting point is 00:15:01 Provide the physical support and protection for drop cable plant from the pole to the customer premises. transition cable plant from the aerial network to underground and buried plant, provide the means for safe and effective grounding, bonding, and isolation connections for the metallic and dialectic components of the network. Functional performance requirements common to pole line hardware for utility poles made of wood, steel, concrete, or fiber-reinforced composite FRC materials are contained in Telcordia, GR-3174. Generic requirements for hardware attachments for utility poles.
Starting point is 00:15:48 Attachment hardware by pull type. Woodpoles The traditional wood pole material provides great flexibility during placement of hardware and cable apparatus. Holes are easily drilled to fit the exact hardware needs and requirements. In addition, fasteners, as lags and screws are easily applied to wood structures to support outside plant OSP apparatus. Non-wood poles There are three main non-wood pole materials and structures on which the attachment hardware may be mounted.
Starting point is 00:16:24 Concrete, steel, and fiber-reinforced composite FRC. Each material has intrinsic characteristics that need to be considered during the design a manufacture of the attachment hardware. attachment hardware. Concrete poles. The most widespread use of concrete poles is in marine environments and coastal zones. Or excellent corrosion resistance is required to reduce the impact of seawater, salt fog, and corrosive soil conditions, e.g. Marsh. Their heavy weight also helps the concrete poles resist the high winds possible in coastal areas. The various designs for concrete poles include tapered structures and round poles made of solid concrete, pre-stressed concrete, spun cast, or statically cast, and a hybrid of concrete and steel. The drilling of installed
Starting point is 00:17:22 concrete poles is not feasible. Users may wish to have the attachment hardware cast into the concrete during the pole manufacture. As a result of these operational difficulties, banded hardware has become the more popular means to attach cable plant to concrete poles. Design criteria and requirements for concrete poles can be derived from various industry documents including, but not limited to, ASCE-11, ACI-318, ASTM-C-935, and ASTM C-1089. steel poles can provide advantages for high voltage lines where taller poles are required for enhanced clearances and longer span requirements. Tubular steel poles are typically made from 11-gauge galvanized steel with thicker 10 or 17-gauge materials used for some taller poles because of their higher strength and rigidity. For tall tower-type structures, 5-gauge materials are used.
Starting point is 00:18:36 Although steel poles can be drilled on site with an annular drill bit or standard twist drill bit, it is not a recommended practice. As with concrete poles, bolt holes could be built into the steel pole during manufacture for use as general attachment points or places for steps to be bolted into the pole. Welding of attachment hardware or attachment ledges to steel poles may be a feasible alternative approach to help provide reliable attachment points. However, operational and practical hazards of welding in the field may make this process undesirable and uneconomical. Steel poles should meet industry specifications, such as TIA-E-I-A-2-2-G, structural standard for antennae-supporting
Starting point is 00:19:34 structures and antennas. TIAEIA-2-222. Structural Standards for Steel and TIA-E-I-A-R-S-2-2-2 or an equivalent requirement set to help ensure a robust and good-quality pull is being used. Fiber-reinforced composite FRC poles. FRC poles cover a family of pole materials that combine fiberglass,
Starting point is 00:20:05 fiber strength members, with a cross-linked polyester resin, and a variety of chemical additives to produce a lightweight weather-resistant structure. FRC poles are hollow and similar to the tubular steel poles, with a typical wall thickness of a quarter to a half inch, with an outer polyurethane coating that is roughly 0.002 inches thin. As with all the other non-wood poles, FRC poles cannot be mounted with the traditional climbing hardware of hooks and gaffs. FRC poles can be pre-drilled by the manufacturer or holes can be drilled on site. Attachments using lag bolts, teeth, nails, and staples are unacceptable for FRC poles. Through bolts are used instead of lag bolts for maximum bonding to the pole and to avoid loosening of hardware.
Starting point is 00:21:07 The relevant industry documents covering FRC polls includes ASTM D-4923, ANSI-C-136.20, OPC-03-03-0-0-0-02, Antelcordia GR-3159, generic requirements for fiber-reinforced composite FRC, concrete, and steel utility poles. In some countries such as the United Kingdom, utility poles have sets of brackets arranged in a standard pattern up the pole to act as hand and footholds so that maintenance and repair workers can climb the pole to work on the lines. In the United States, such steps have been determined to be a public hazard and are no longer allowed on new poles. linemen may use climbing spikes called gaffs to ascend wooden poles without steps on them. In the UK, boots fitted with steel loops that go around the pole, known as Scandinavian climbers,
Starting point is 00:22:19 are also used for climbing poles. In the U.S., linemen use bucket trucks for the vast majority of poles that are accessible by vehicle. The poles at the end of a straight section of utility line where the line ends or angles off in another direction are called dead end poles in the United States. Elsewhere they may be referred to as anchor or termination poles. These must carry the lateral tension of the long straight sections of wire. They are usually made with heavier construction. The power lines are attached to the pole by horizontal strain insulators, either placed on crossarms which are either doubled, tripled, or replaced with a steel crossarm to provide more resistance to the tension forces,
Starting point is 00:23:15 or attached directly to the pole itself. Dead end and other poles that support lateral loads have guy wires to support them. The guys always have strain insubes. insulators inserted in their length to prevent any high voltages caused by electrical faults from reaching the lower portion of a cable that is accessible by the public. In populated areas, guywires are often encased in a yellow plastic or wood tube with reflectors attached to their lower end so that they can be seen more easily, reducing the chance of people and animals walking into them or vehicles crashing into them.
Starting point is 00:24:03 Another means of providing support for lateral loads is a push-brace pole, a second shorter pole that is attached to the side of the first and runs at an angle to the ground. If there is no space for a lateral support, a stronger pole, e.g. a construction of concrete or iron has used. The system of suspending telegraph wires from poles with ceramic insulators was invented and patented by British telegraph pioneer William Fothergill Cook. Cook was the driving force in establishing the electrical telegraph on a commercial basis. With Charles Wheatstone, he invented the Cook and Wheatstone Telegraph
Starting point is 00:24:50 and founded the world's first telegraph company, the Electric Telegraph Company. Telegraph poles were first used on the Great Western Railway in 1843, when the Cook and Wheatstone Telegraph line was extended to Slough. The line had previously used buried cables, but that system had proved troublesome with failing insulation. In Britain, the trees used for telegraph poles were either native larch or pine from Sweden and Norway. Poles in early installations were treated with tar, but these were found to last only around seven years. Later poles were treated instead with creosode or copper sulfate for the preservative.
Starting point is 00:25:43 Utility poles were first used in the mid-19th century in America with telegraph systems. In 1844, the United States Congress granted Samuel Morris $30,000, equivalent to $942,000. $2,200 in 2022 to build a 40-mile telegraph line between Baltimore, Maryland, and Washington, D.C. Morse began by having a lead-sheathed cable made. After laying seven miles underground, he tested it. He found so many faults with his system that he dug up his cable, stripped off its sheath, bought poles, and strung his wires overhead. On February 7, 18, Morse inserted the following advertisement in the Washington newspaper. Sealed proposals will be received by the undersigned for furnishing 700 straight and sound chestnut posts,
Starting point is 00:26:41 with the bark on and of the following dimensions to wit. Each post must not be less than 8 inches in diameter at the butt, and tapering to 5 or 6 inches at the top. 680 of said posts to be 24 feet in length and 20 of them 30 feet in length. In some parts of Australia, wooden poles are rapidly destroyed by termites, so metal poles must be used instead, and in much of the interior, wooden poles are vulnerable to fire. The Oppenheimer pole is a collapsible wrought iron pole in three sections. It is named after Oppenheimer and Company and John.
Starting point is 00:27:26 Germany, but they were mostly manufactured in England under license. They were used on the Australian Overland Telegraph line built in 1872, which connected the continent north to south directly through the center and linked to the rest of the world throughout a submarine cable at Darwin. The Stoby pole was invented in 1924 by James Cyril Stobie of the Adelaide Electric Supply company, and first used in South Terrace, Adelaide. One of the early Bell system lines was the Washington, D.C. Norfolk line, which was, for the most part, square sawn tapered poles of yellow pine, probably treated to refusal with creosode.
Starting point is 00:28:13 Treated to refusal means that the manufacturer forces preservatives into the wood, until it refuses to accept more, but performance is not guaranteed. Some of these were still in service after 80 years. The building of pole lines was resisted in some urban areas in the late 19th century, and political pressure for undergrounding remains powerful in many countries. In Eastern Europe, Russia, and Third World countries, many utility poles still carry bare communication wires mounted on the insulators not only along railway lines,
Starting point is 00:28:51 but also along roads and sometimes even in urban areas. Aerrant traffic being uncommon on railways, their poles are usually less tall. In the United States, electricity is predominantly carried on unshielded aluminum conductors, wound around a solid steel core, and affixed to rated insulators made from glass, ceramic, or poly. Telephone, CATV, and FOCs, are generally attached directly to the pole without insulators.
Starting point is 00:29:25 In the United Kingdom, much of the rural electricity distribution system is carried on wooden poles. These normally carry electricity at 11 or 33 kilovolts, three phases, from 132-kilovol substations supplied from pylons to distribution substations or pole-mounted transformers. Wooden poles have been used for 132-kilovolts. kilowatts for a number of years. From the early 1980s, one is called the Trident. They are usually used on short sections, though the line from Melbourne, CAMs to New Bundingford, Arts, is quite long. The conductors on these are bare metal connected to the posts by insulators. Wood poles can also be used for low voltage distribution to customers. Today, utility poles may hold much more than the
Starting point is 00:30:22 uninsulated copper wire that they originally supported. Thicker cables holding many twisted pair, coaxial cable, or even fiber optic, may be carried. Simple analog repeaters or other outside plant equipment have long been mounted against poles, and often new digital equipment for multiplexing demultiplexing or digital repeaters may now be seen. In many places, providers of electricity, television, telephone, street light, traffic signal, and other services share poles, either in joint ownership or by renting space to each other. In the United States, ANSI standard 0.5.1.208 governs wood pole sizes and strength loading. Utilities that fall under the Rural Electrification Act must also follow the guidelines set forth in RU.S. Bulletin 1724E-150 from the U.S. Department of Agriculture for pole strength and loading. Steel utility poles are becoming more prevalent in the United States, thanks to improvements in engineering and corrosion prevention coupled with lower production costs.
Starting point is 00:31:43 However, premature failure due to corrosion is a concern when compared to wood. The National Association of Corrosion Engineers Archive 2010-619 at the Wayback Machine, or NACE, is developing inspection, maintenance, and prevention procedures similar to those used on wood utility poles to identify and prevent decay. British telecom posts are usually marked with the following information. BT, to mark it as a British Telecom UK poll, this can also be PO Post Office or GPO General Post Office, depending on the age of the pole. A horizontal line marking 3 meters from the bottom of the pole. The pole length, typically 8 to 10 meters and size. 9L is a 9 meters long light pole Other letters used are M medium
Starting point is 00:32:47 N S stout The year of treatment and therefore generally the year of installation The batch and type of wood used A date of the last official inspection An alpha numeric designation EG DP 242 Where DP is an initialism of district distribution point. If relevant, a red D plate meaning dangerous and indicating that the pole was
Starting point is 00:33:17 structurally unsafe to climb or due to its proximity to other hazards. The date on the pole is applied by the manufacturer and refers to the date the pole was preserved, treated to withstand the elements. In the United States, utility poles are marked with information concerning the manufacturer, pole hide, ANSI's strength class, wood species, original preservative, and year manufactured, vintage, in accordance with ANSI standard 0.5.1.208. This is called branding, as it is usually burned into the surface. The resulting mark is sometimes called the birth mark. Although the position of the brand is determined by ANSI's specification, it is essentially just below eye level after installation.
Starting point is 00:34:14 A rule of thumb for understanding a pole's brand is the manufacturer's name or logo at the top, with a two-digit date beneath, sometimes preceded by a month. Below the date is a two-character wood species abbreviation and one-to-three-character preservative. Some wood species may be marked SP for Southern Pine, WC for Western Cedar, or D.F for Douglas fir. Common preservative abbreviations are C for Creeosode, P for Pentacloraphynal, and SK for chromated copper arsenate, originally referred to salts type K. The next line of the brand is usually the people's anclyclas, used to determine maximum load. This number ranges from 10 to H6,
Starting point is 00:35:08 with a smaller number meaning higher strength. The pole's height from butt to top in five-foot increments is usually to the right of the class separated by a hyphen, although it is not uncommon for older brands to have the height on a separate line. The pole brand is sometimes an aluminum tag nailed in place. Before the practice of branding, many utilities would set a two-to-four-digit date nail into the pole upon installation. The use of date nails went out of favor during World War II to war shortages, but is still used by a few utilities. These nails are considered valuable to collectors, with older dates being more valuable, and unique markings such as the utility's name also increasing the value.
Starting point is 00:36:01 However, regardless of the value to collectors, all attachments on a utility pole are the property of the utility company, and unauthorized removal is a misdemeanor or felony. A pole route or pole line in the U.S. is a telephone link or electrical power line between two or more locations by way of multiple uninsulated wires suspended between wooden utility poles. This method of link is common, especially in rural areas, where burying the cables would be expensive. Another situation in which pole routes were extensively used were on the railway to link signal boxes. Traditionally, prior to around 1965, pole routes were built with open wires along non-electrical operated railways. This necessitated insulation when the wire passed over the pole. thus preventing the signal from becoming attenuated. At electrical operated railways,
Starting point is 00:37:06 pole routes were usually not built as too much jamming from the overhead wire would occur. To accomplish this, cables were separated using spars with insulators spaced along them. In general, four insulators were used per spar. Only one such pole route still exists on the UK Rail Network in the highlands of Scotland. There was also a long section in place between Wimdom, Norfolk, and Brandon in Suffolk, United Kingdom. However, this was de-wired and removed during March 2009. Utility poles are used by birds for nesting and to rest on.
Starting point is 00:37:48 Utility poles and related structures are regarded by some to be a form of visual pollution. Many lines are placed underground for this reason, in places of, high population density or scenic beauty that justify the expense. Architects designed some pylons to be pretty, thus avoiding visual pollution. Some chemicals used to preserve woodpoles, including creosodin pentoclorophyll, are toxic and have been found in the environment. A considerable improvement of weathering resistance offered by creosote infusion has long-term drawbacks. In recent years, concerns have been raised about the toxicity of creosote-treated
Starting point is 00:38:34 wood waste, such as utility poles. Specifically, their biodegration can release phenolic compounds in soil, which are considered toxic. Research continues to explore methods to render this waste safe for disposal. Historically, pole-mounted transformers were filled with the polychlorinated bifanol, PCB liquid. PCBs persist in the environment and have adverse effects on animals.

There aren't comments yet for this episode. Click on any sentence in the transcript to leave a comment.